logo
جودة 0-10MΩ Insulation Monitoring Device Power Supply Equipment DC24V~1500V مصنع
<
جودة 0-10MΩ Insulation Monitoring Device Power Supply Equipment DC24V~1500V مصنع
جودة 0-10MΩ Insulation Monitoring Device Power Supply Equipment DC24V~1500V مصنع
>

0-10MΩ Insulation Monitoring Device Power Supply Equipment DC24V~1500V

ملخص المنتج

Insulation Testing Device with 0-10 MΩ Monitoring Range Dual-Bus Monitoring and Hierarchical Alarms for Accurate Fault Detection Insulation Testing Device Functional Features Monitoring range: 0-10 MΩ (extendable up to 100 MΩ), accuracy ±5%, resolution ≤1 kΩ Dual-bus monitoring: Independently ...

سمات المنتج المخصصة

نطاق مقاومة العزل:
0.1 كيلو أوم ~ 10 ميجا أوم
دقة القياس:
±0.5% (النطاق الكامل)
نطاق مراقبة الجهد:
تيار مستمر 24 فولت ~ 1500 فولت
وقت الاستجابة:
≥5 ثانية (المسح على مستوى النظام)
جهد العمل:
تيار مستمر 85 فولت ~ 265 فولت
درجة حرارة العمل:
-40 ℃ ~+70 ℃
إبراز:

10MΩ Insulation Monitoring Device

,

Power Supply Equipment DC24V

,

1500V Insulation Monitoring Device

الخصائص الأساسية

مكان المنشأ:
شنتشن، مقاطعة قوانغدونغ، الصين
اسم العلامة التجارية:
Shenzhen Hongyi Technology Co.,Ltd
رقم الموديل:
ش-إنسم

تداول العقارات

الحد الأدنى لكمية:
1
الأسعار:
RMB 1499
وقت التسليم:
10-14 يوم عمل
شروط الدفع:
تي/تي
القدرة على العرض:
30

وصف المنتج

Insulation Testing Device with 0-10 MΩ Monitoring Range Dual-Bus Monitoring and Hierarchical Alarms for Accurate Fault Detection

 

Insulation Testing Device
Functional Features
  • Monitoring range: 0-10 MΩ (extendable up to 100 MΩ), accuracy ±5%, resolution ≤1 kΩ
  • Dual-bus monitoring: Independently measures insulation resistance between positive and negative electrodes to ground
  • Supports hierarchical alarms (early warnings and alerts) with customizable thresholds
  • Branch circuit inspection: Identifies faulty insulated branches using sampling resistor switching
  • Distinguishes between fault types including single-pole grounding and bipolar unbalanced grounding
  • Adaptive monitoring mode: Automatically adjusts measurement modes based on system voltage fluctuations
  • Supports host, extension, and slave operation modes
  • Supports coordinated testing of system interconnection faults between master and slave devices
  • Supports main handset mode for split-screen designs
  • Compatible with both digital and analog leakage current sensors
  • Modular design with parameter import via USB drive
  • Flexible configuration: Integrates with DC monitoring devices or standalone human-machine interface
  • Automatic switching of bridge resistor values for 110V/220V system adaptation
Technical Specifications
Monitoring Parameters
Parameter Item Typical Value/Range Description
Insulation resistance measurement range 0.1kΩ~10MΩ High-resistance range for high-voltage systems (photovoltaic, energy storage); low-resistance range for precise alarms
Measurement accuracy ±0.5% (full range) High-precision design ensures reliable leakage current warning performance
Voltage Monitoring Range DC 24V~1500V Compatible with wide voltage ranges including communication base stations (48V), substations (220V), and photovoltaic systems (1500V)
Resolution ≤1 kΩ (insulation resistance); ≤0.1 V (bus voltage) High resolution enables analysis of subtle insulation degradation trends
Response time ≤5 seconds (system-wide scan) Quickly detect insulation degradation with branch localization time ≤30 seconds
Fault Localization and Performance Parameters
Parameter Item Typical Value/Range Description
Branch positioning accuracy ±5% (insulation resistance)  
Fault Type Identification Unipolar grounding, bipolar unbalanced grounding, capacitive grounding  
Capacitive Compensation Function Supports ground capacitance ≤ 100 μF  
Communication and Interface Parameters
Parameter Item Typical Value/Range Description
Communication Interface RS485 Supports Modbus RTU protocol
Alarm Output Dry contact signal (passive contact) Always-on/always-off contact, rated capacity 250 V AC/5 A, directly drives relay or audio-visual alarm
Data storage ≥100,000 event records Stores historical insulation resistance data and fault events with timestamps; supports export to USB drives
SOE resolution ≤1ms Records sequence of fault occurrences for multi-system collaborative analysis
Electrical and Environmental Adaptability
Parameter Item Typical Value/Range Description
Working voltage DC85V~265V Wide voltage input, compatible with 110V/220V DC systems
Power 12V60W Supports power supply for up to 720 digital CT units
Working temperature -40℃~+70℃  
Safety and Reliability Parameters
Parameter Item Typical Value/Range Description
Isolation Voltage ≥2500 V AC Between input, output, and communication circuits; suppresses transient overvoltages from surges or lightning strikes
Surge protection 8/20 μs surge current: 20 kA (IEC 61000-4-5) Prevents equipment damage caused by wiring errors
Self-checking function Power-on self-test (bridge arm resistance, ADC, communication) Ensures long-term equipment reliability