24V-1500V DC Power Monitor Industrial Monitor RS485 CAN Ethernet USB Communication
สรุปผลิตภัณฑ์
DC System Monitoring with Precision ±0.2% Busbar Voltage Monitoring, RS485 CAN Ethernet USB Communication, and Industrial Grade -20°C to +70°C Operation DC System Monitoring – Technical Parameters monitoring parameter Parameter Item Typical Value/Range explain Input Power Monitoring AC 25V–265V or ...
คุณสมบัติที่กําหนดเองของสินค้า
1500V DC Power Monitor
,24V DC Power Monitor
,RS485 Industrial Monitor
คุณสมบัติพื้นฐาน
การซื้อขายอสังหาริมทรัพย์
รายละเอียดสินค้า
DC System Monitoring with Precision ±0.2% Busbar Voltage Monitoring, RS485 CAN Ethernet USB Communication, and Industrial Grade -20°C to +70°C Operation
| monitoring parameter | ||
|---|---|---|
| Parameter Item | Typical Value/Range | explain |
| Input Power Monitoring | AC 25V–265V or DC 36V–375V | Supports 48V/110V/220V systems |
| Busbar voltage monitoring | DC 24V~1500V | Precision ±0.2%, Resolution 0.1 V |
| Battery Management | Single-cell voltage: 0–16 V (lead-acid) | Supports SOC (±3%) and SOH (±5%) estimation, with charging/discharging current accuracy of ±0.5%. |
| Feeder circuit monitoring | Up to 1024 digital signal channels | |
| Insulation Resistance Monitoring | 0.1kΩ~10MΩ, accuracy ±5% | Branch positioning accuracy: ±5% |
| Integrated Centralized Monitoring | Features small-scale integrated monitoring capabilities | Supports the integration of AC systems, charging modules, DC-DC modules, battery inspection systems, inverters, and insulation monitoring subsystems. |
| Communication and Intelligence Parameters | ||
|---|---|---|
| Parameter Item | Typical Value/Range | explain |
| CI | RS485, CAN, Ethernet, USB | Supports Modbus RTU/TCP, IEC 61850, and DNP3 protocols, enabling seamless integration with SCADA/BMS systems. |
| telecontrol | Switching on/off, switching between charging and discharging modes, parameter configuration | Supports remote operation via Web/APP with permission-level management (administrator/operator). |
| data storage | ≥100,000 records (cyclic storage with timestamps) | Record voltage, current, and alarm events, with support for CSV/Excel export. |
| Human-Machine Interface (HMI) | 7-inch touchscreen, Resolution: 800*480 | Real-time data display, historical curve analysis, alarm pop-ups, and operation log queries. |
| Protection and Reliability Parameters | ||
|---|---|---|
| Parameter Item | Typical Value/Range | explain |
| Overvoltage/Undervoltage Protection | Response time ≤ 10 ms, triggered by both hardware and software | |
| Overcurrent/Short Circuit Protection | Hierarchical protection (alert/trip), accuracy ±2% | The electronic circuit breaker or fuse trips, automatically isolating the power supply line after a fault occurs. |
| Lightning Protection and Surge Protection | 8/20 μs surge current: 20 kA (IEC 61000-4-5) | The input/output terminals integrate a TVS diode, a varistor, and a gas discharge tube. |
| Environmental Adaptability Parameters | ||
|---|---|---|
| Parameter Item | Typical Value/Range | explain |
| working temperature | -20°C to +70°C (Industrial grade) | The wide-temperature model can operate across a range of-40°C to +85°C (e.g., for outdoor substations). |
| levels of protection | IP54 | |
| Seismic Performance | 5Hz~150Hz/5Grms(IEC 60068-2-6) | Applications such as rail transit and maritime vessels require customized higher seismic resistance ratings (e.g., 10 Grms). |
| Humidity Range | 5% to 95% (non-condensable) | Supports condensation protection design (e.g., heating modules). |
| Mechanical and Installation Parameters | |
|---|---|
| Parameter Item | Typical Value/Range |
| way to install | flushbonading |
| outline dimension | 240 mm * 160 mm * 54 mm (width * height * depth) |
| weight | ≤500 g (excluding external sensors and cables) |