logo
गुणवत्ता Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion कारखाना
<
गुणवत्ता Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion कारखाना
>

Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion

उत्पाद सारांश

Telecom Power Monitor with Multi-channel Parallel Expansion Automatic Switching and N+1 Module Redundancy Telecom Power Monitor Monitoring Parameters Parameter Item Typical Value/Range Description Input Power Monitoring DC 36V~120V Output Voltage/Current DC-48V (communication standard) ±1%, 0-600 A ...

उत्पाद कस्टम विशेषताएँ

इनपुट पावर मॉनिटरिंग:
डीसी 36वी~120वी
आउटपुट वोल्टेज / करंट:
DC-48V (संचार मानक) ±1%,0-600 A
बैटरी प्रबंधन:
एकल-सेल वोल्टेज: 0-16 वी (लेड-एसिड) / 0-5 वी (लिथियम बैटरी)
वितरण शाखा की निगरानी:
शाखा धारा: 0-100 ए, सटीकता ±1%
फीडर का पता लगाना:
1024 फीडर लाइनों के लिए ट्रिप स्थिति और स्थान संकेतों की निगरानी का समर्थन करता है
संचार इंटरफेस:
आरएस485, ईथरनेट, एसएनएमपी, वाईफाई
प्रमुखता देना:

Automatic Switching Telecom Monitor

,

Telecom Monitor Industrial

,

Industrial Monitor Multi Channel

मूलभूत गुण

उत्पत्ति के प्लेस:
शेन्ज़ेन, गुआंग्डोंग प्रांत, चीन
ब्रांड नाम:
Shenzhen Hongyi Technology Co.,Ltd
मॉडल संख्या:
SH-COMM07R

व्यापारिक संपत्तियाँ

न्यूनतम आदेश मात्रा:
1
मूल्य:
RMB 1499
प्रसव के समय:
10-14 कार्य दिवस
भुगतान शर्तें:
टी/टी
आपूर्ति की क्षमता:
30

उत्पाद वर्णन

Telecom Power Monitor with Multi-channel Parallel Expansion Automatic Switching and N+1 Module Redundancy

 

Telecom Power Monitor
Monitoring Parameters
Parameter Item Typical Value/Range Description
Input Power Monitoring DC 36V~120V  
Output Voltage/Current DC-48V (communication standard) ±1%, 0-600 A Precision: ±0.5%; supports multi-channel parallel expansion; overload capacity ≥120% (10 s)
Battery Management Single-cell voltage: 0-16 V (lead-acid) / 0-5 V (lithium battery) SOC estimation accuracy: ±3%; charge/discharge current accuracy: ±0.5%; supports automatic switching between even float charging modes
Distribution Branch Monitoring Branch current: 0-100 A, accuracy ±1% Monitor current levels in all load branches; overcurrent protection response time ≤50 ms
Feeder Detection Supports monitoring of trip status and location signals Capable of monitoring up to 1024 feeder lines
Run Mode Supports various busbar configurations One-to-one charging, one-to-two charging, two-to-two charging configurations
Communication and Intelligence Parameters
Parameter Item Typical Value/Range Description
Communication Interface RS485, Ethernet, SNMP, WiFi Supports Modbus RTU/TCP and SNMPv3 protocols; enables seamless integration with power and environmental monitoring or network management systems
Telemanagement Parameter configuration, firmware upgrade, fault reset Supports operations on Web, APP, and cloud platforms; compatible with mainstream platforms including Tower, Huawei, and ZTE
Data Storage ≥50,000 records (cyclic storage with timestamps) Records voltage, current, and alarm events; supports local export or cloud synchronization
Human-Machine Interface (HMI) 7-inch LCD screen, 800*480 pixels resolution Real-time status display, historical curve queries, alarm logs, and operation menus
Protection and Reliability Parameters
Parameter Item Typical Value/Range Description
Input Protection Overvoltage/undervoltage/phase loss protection, response time ≤10 ms Quick hardware disconnection to prevent equipment damage caused by grid abnormalities
Output Protection Overcurrent/short-circuit/reverse connection protection, accuracy ±2% Electronic circuit breaker or fuse trips to isolate faults; supports automatic recovery (optional)
Battery Protection Supports secondary power-off functionality  
Lightning and Surge Protection 8/20 μs surge current: 20 kA (IEC 61000-4-5) Input/output terminals feature integrated three-level lightning protection (MOV + GDT + TVS)
Redundancy Design N+1 module redundancy with hot-swappable capability Automatically switches during single-module failure to ensure uninterrupted power supply
MTBF ≥100,000 hours High-reliability design meeting 24/7 operational requirements of telecommunications industry
Environmental Adaptability Parameters
Parameter Item Typical Value/Range
Working Temperature -40°C to +70°C (outdoor type)
Protection Level IP65 (whole unit)
Seismic Performance 10Hz~500Hz/10Grms (EN 50155)
Humidity Range 5% to 95% (non-condensable)

हमारे विशेषज्ञों से संपर्क करें और मुफ्त परामर्श प्राप्त करें!

हमारा मिशन हमारे ग्राहकों को अधिक लाभ कमाने में मदद करने के लिए "उच्च गुणवत्ता" और "अच्छी सेवा" और "त्वरित वितरण" प्रदान करना है।