logo
Qualité Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion Usine
<
Qualité Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion Usine
>

Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion

Résumé du produit

Telecom Power Monitor with Multi-channel Parallel Expansion Automatic Switching and N+1 Module Redundancy Telecom Power Monitor Monitoring Parameters Parameter Item Typical Value/Range Description Input Power Monitoring DC 36V~120V Output Voltage/Current DC-48V (communication standard) ±1%, 0-600 A ...

Attributs personnalisés du produit

Surveillance de la puissance d'entrée:
C.C 36 V ~ 120 V
Tension de sortie/actuel:
DC-48V (norme de communication) ±1%,0-600 A
Gestion de la batterie:
Tension d'une seule cellule : 0-16 V (plomb-acide) / 0-5 V (batterie au lithium)
Surveillance des succursales de distribution:
Courant de dérivation : 0-100 A, précision ±1 %
Détection du chargeur:
Prend en charge la surveillance de l'état de déclenchement et des signaux de localisation pour 1
Interface de communication:
RS485, Ethernet, SNMP, Wi-Fi
Mettre en évidence:

Automatic Switching Telecom Monitor

,

Telecom Monitor Industrial

,

Industrial Monitor Multi Channel

Propriétés de base

Lieu d'origine:
Shenzhen, province du Guangdong, Chine
Nom de marque:
Shenzhen Hongyi Technology Co.,Ltd
Numéro de modèle:
SH-COMM07R

Propriétés commerciales

Quantité de commande min:
1
Prix:
RMB 1499
Délai de livraison:
10-14 jours de travail
Conditions de paiement:
T/T
Capacité d'approvisionnement:
30

Description du produit

Telecom Power Monitor with Multi-channel Parallel Expansion Automatic Switching and N+1 Module Redundancy

 

Telecom Power Monitor
Monitoring Parameters
Parameter Item Typical Value/Range Description
Input Power Monitoring DC 36V~120V  
Output Voltage/Current DC-48V (communication standard) ±1%, 0-600 A Precision: ±0.5%; supports multi-channel parallel expansion; overload capacity ≥120% (10 s)
Battery Management Single-cell voltage: 0-16 V (lead-acid) / 0-5 V (lithium battery) SOC estimation accuracy: ±3%; charge/discharge current accuracy: ±0.5%; supports automatic switching between even float charging modes
Distribution Branch Monitoring Branch current: 0-100 A, accuracy ±1% Monitor current levels in all load branches; overcurrent protection response time ≤50 ms
Feeder Detection Supports monitoring of trip status and location signals Capable of monitoring up to 1024 feeder lines
Run Mode Supports various busbar configurations One-to-one charging, one-to-two charging, two-to-two charging configurations
Communication and Intelligence Parameters
Parameter Item Typical Value/Range Description
Communication Interface RS485, Ethernet, SNMP, WiFi Supports Modbus RTU/TCP and SNMPv3 protocols; enables seamless integration with power and environmental monitoring or network management systems
Telemanagement Parameter configuration, firmware upgrade, fault reset Supports operations on Web, APP, and cloud platforms; compatible with mainstream platforms including Tower, Huawei, and ZTE
Data Storage ≥50,000 records (cyclic storage with timestamps) Records voltage, current, and alarm events; supports local export or cloud synchronization
Human-Machine Interface (HMI) 7-inch LCD screen, 800*480 pixels resolution Real-time status display, historical curve queries, alarm logs, and operation menus
Protection and Reliability Parameters
Parameter Item Typical Value/Range Description
Input Protection Overvoltage/undervoltage/phase loss protection, response time ≤10 ms Quick hardware disconnection to prevent equipment damage caused by grid abnormalities
Output Protection Overcurrent/short-circuit/reverse connection protection, accuracy ±2% Electronic circuit breaker or fuse trips to isolate faults; supports automatic recovery (optional)
Battery Protection Supports secondary power-off functionality  
Lightning and Surge Protection 8/20 μs surge current: 20 kA (IEC 61000-4-5) Input/output terminals feature integrated three-level lightning protection (MOV + GDT + TVS)
Redundancy Design N+1 module redundancy with hot-swappable capability Automatically switches during single-module failure to ensure uninterrupted power supply
MTBF ≥100,000 hours High-reliability design meeting 24/7 operational requirements of telecommunications industry
Environmental Adaptability Parameters
Parameter Item Typical Value/Range
Working Temperature -40°C to +70°C (outdoor type)
Protection Level IP65 (whole unit)
Seismic Performance 10Hz~500Hz/10Grms (EN 50155)
Humidity Range 5% to 95% (non-condensable)

Contactez nos experts et obtenez une consultation gratuite!