logo
جودة Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion مصنع
<
جودة Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion مصنع
>

Automatic Switching Telecom Monitor Industrial Monitor Multi Channel Parallel Expansion

ملخص المنتج

Telecom Power Monitor with Multi-channel Parallel Expansion Automatic Switching and N+1 Module Redundancy Telecom Power Monitor Monitoring Parameters Parameter Item Typical Value/Range Description Input Power Monitoring DC 36V~120V Output Voltage/Current DC-48V (communication standard) ±1%, 0-600 A ...

سمات المنتج المخصصة

مراقبة طاقة الإدخال:
تيار مستمر 36 فولت ~ 120 فولت
جهد الإخراج / الحالي:
DC-48V (معيار الاتصال) ±1%,0-600 أمبير
إدارة البطارية:
جهد الخلية الواحدة: 0-16 فولت (حمض الرصاص) / 0-5 فولت (بطارية الليثيوم)
مراقبة فرع التوزيع:
تيار الفرع: 0-100 أمبير، الدقة ±1%
كشف المغذية:
يدعم مراقبة حالة الرحلة وإشارات الموقع لـ 1024 خط تغذية
واجهة الاتصالات:
RS485، إيثرنت، SNMP، واي فاي
إبراز:

Automatic Switching Telecom Monitor

,

Telecom Monitor Industrial

,

Industrial Monitor Multi Channel

الخصائص الأساسية

مكان المنشأ:
شنتشن، مقاطعة قوانغدونغ، الصين
اسم العلامة التجارية:
Shenzhen Hongyi Technology Co.,Ltd
رقم الموديل:
ش-COMM07R

تداول العقارات

الحد الأدنى لكمية:
1
الأسعار:
RMB 1499
وقت التسليم:
10-14 يوم عمل
شروط الدفع:
تي/تي
القدرة على العرض:
30

وصف المنتج

Telecom Power Monitor with Multi-channel Parallel Expansion Automatic Switching and N+1 Module Redundancy

 

Telecom Power Monitor
Monitoring Parameters
Parameter Item Typical Value/Range Description
Input Power Monitoring DC 36V~120V  
Output Voltage/Current DC-48V (communication standard) ±1%, 0-600 A Precision: ±0.5%; supports multi-channel parallel expansion; overload capacity ≥120% (10 s)
Battery Management Single-cell voltage: 0-16 V (lead-acid) / 0-5 V (lithium battery) SOC estimation accuracy: ±3%; charge/discharge current accuracy: ±0.5%; supports automatic switching between even float charging modes
Distribution Branch Monitoring Branch current: 0-100 A, accuracy ±1% Monitor current levels in all load branches; overcurrent protection response time ≤50 ms
Feeder Detection Supports monitoring of trip status and location signals Capable of monitoring up to 1024 feeder lines
Run Mode Supports various busbar configurations One-to-one charging, one-to-two charging, two-to-two charging configurations
Communication and Intelligence Parameters
Parameter Item Typical Value/Range Description
Communication Interface RS485, Ethernet, SNMP, WiFi Supports Modbus RTU/TCP and SNMPv3 protocols; enables seamless integration with power and environmental monitoring or network management systems
Telemanagement Parameter configuration, firmware upgrade, fault reset Supports operations on Web, APP, and cloud platforms; compatible with mainstream platforms including Tower, Huawei, and ZTE
Data Storage ≥50,000 records (cyclic storage with timestamps) Records voltage, current, and alarm events; supports local export or cloud synchronization
Human-Machine Interface (HMI) 7-inch LCD screen, 800*480 pixels resolution Real-time status display, historical curve queries, alarm logs, and operation menus
Protection and Reliability Parameters
Parameter Item Typical Value/Range Description
Input Protection Overvoltage/undervoltage/phase loss protection, response time ≤10 ms Quick hardware disconnection to prevent equipment damage caused by grid abnormalities
Output Protection Overcurrent/short-circuit/reverse connection protection, accuracy ±2% Electronic circuit breaker or fuse trips to isolate faults; supports automatic recovery (optional)
Battery Protection Supports secondary power-off functionality  
Lightning and Surge Protection 8/20 μs surge current: 20 kA (IEC 61000-4-5) Input/output terminals feature integrated three-level lightning protection (MOV + GDT + TVS)
Redundancy Design N+1 module redundancy with hot-swappable capability Automatically switches during single-module failure to ensure uninterrupted power supply
MTBF ≥100,000 hours High-reliability design meeting 24/7 operational requirements of telecommunications industry
Environmental Adaptability Parameters
Parameter Item Typical Value/Range
Working Temperature -40°C to +70°C (outdoor type)
Protection Level IP65 (whole unit)
Seismic Performance 10Hz~500Hz/10Grms (EN 50155)
Humidity Range 5% to 95% (non-condensable)