logo
Qualität Intelligent Data Acquisition Server Communication 70V~265VAC 24V~400VDC Fabrik
<
Qualität Intelligent Data Acquisition Server Communication 70V~265VAC 24V~400VDC Fabrik
>

Intelligent Data Acquisition Server Communication 70V~265VAC 24V~400VDC

Produktübersicht

Intelligent Communication Data Acquisition Server Intelligent Communication Data Acquisition Server with Edge Computing, High-Performance Concurrent Processing, and Large-Capacity Storage for Power Distribution Substations Product Overview The SH-PEVM99 Intelligent Communication Acquisition Server ...

Produktanpassungsattribute

Stromversorgung:
70~265VAC,24~400VDC
DC-Ausgang:
12V
Gesamtstromverbrauch:
≤30W
Prozessor:
ARM Cortex-A7 800 MHz, ARM Cortex-M4 240 MHz
Innenlagerung:
≥1GB
Erinnerung:
≥8 GB, 30 Tage Aufbewahrung
Hervorheben:

Intelligent Data Acquisition Server

,

265VAC data acquisition from the server

,

400VDC acquisuite data acquisition server

Grundlegende Eigenschaften

Herkunftsort:
Shenzhen, Provinz Guangdong, China
Markenname:
Shenzhen Hongyi Technology Co.,Ltd
Modellnummer:
SH-PEVM99

Immobilienhandel

Min Bestellmenge:
1
Preis:
RMB 19999 per set
Lieferzeit:
10-14 Arbeitstage
Zahlungsbedingungen:
T/T
Versorgungsmaterial-Fähigkeit:
10

Produktbeschreibung

Intelligent Communication Data Acquisition Server
Intelligent Communication Data Acquisition Server with Edge Computing, High-Performance Concurrent Processing, and Large-Capacity Storage for Power Distribution Substations
Product Overview

The SH-PEVM99 Intelligent Communication Acquisition Server is designed for intelligent transformation and upgrading of power distribution substations, meeting practical grid operation needs while ensuring safe grid performance. It integrates edge computing, containerization, and communication protocol adaptation technologies, featuring a hardware-platform-based, function-software-driven architecture with high-performance concurrent processing capabilities and large-capacity storage. The server supports remote monitoring and inspection of distribution substation operations, enabling unified management of environmental conditions, equipment status, security surveillance, coordinated control, and video monitoring, along with data analysis, statistical reporting, and alarm-triggered alerts.

Working Power Supply Specifications
Project Parameter Remarks
Power Supply Mode 70~265VAC, 24~400VDC  
Rated Voltage AC220V Allowable deviation: -20% to +20%
Rated Frequency 50Hz  
DC Input 24~400VDC Allowable Deviation: -5% to +5%
DC Output 12V  
Total Power Consumption ≤30W  
Backup Source DC24V  
Power Supply Notes:

1) The terminals backup power supply employs a supercapacitor integrated internally, with a charging time of ≤20 minutes. In the event of a main power failure, the supercapacitor automatically takes over to ensure continuous operation for at least 3 minutes and enables at least three data transmissions to the main station.

2) The maintenance-free lifespan of the supercapacitor shall be no less than 8 years.

3) After the terminal is disconnected from the power supply, all configurations, records, and data shall remain preserved for no less than 1 year.

Main Performance Requirements
Project Parameter Remarks
Processor Multi-core heterogeneous processor featuring ARM Cortex-A7 core operating at up to 800 MHz, with two ARM Cortex-M4 240 MHz coprocessors  
System Voltage 0.4kV/10(20)kV  
System Frequency 50Hz  
Internal Storage ≥1GB  
Memory ≥8GB Supports data retention for ≥30 days
Watch Battery Data retention for ≥10 years Clock operation for ≥5 years
Clock Precision ≤2s/d Range: -25°C to +60°C
Reliability (MTBF) ≥20000h  
Height ≤4000m  
Terminal Hardware Interface Requirements
Project Quantity Data Type
Ethernet Port 4 Supports IEC 61850 (NETA, NETB). Supports TCP-MODBUS (NET1, NET2) with 10M/100M adaptive transmission
RS-485 11 Used to collect terminal electrical parameters, switch quantities, equipment parameters, etc.
RS-232/485 3 Optional channel for HMI interface
USB 4 Debugging and USB Drive Data Export
CAN 2 Primary/Secondary
Relay Output 8 For remote control of switching devices such as circuit breakers, fans, dehumidifiers, and lighting systems
Alarm Input 16 Passive input for receiving alarm signals such as smoke, water intrusion, access control, and infrared intrusion
Time Setting 1 Supports IRIG-B for timing purposes

Kontaktieren Sie unsere Experten und erhalten Sie eine kostenlose Beratung!

Unsere Mission ist es, "Hohe Qualität", "Guten Service" und "Schnelle Lieferung" anzubieten, um unseren Kunden zu helfen, mehr Gewinne zu erzielen.