DC Ammeter with 0.2S Accuracy Class and Four and a Half Digits Display Precision Featuring RS485 Communication Interface DC Ammeter Parameters Measurement Specifications Parameter Specification Accuracy Class 0.2S Display Precision Four and a half digits (≥100 A: one decimal place

Product aangepaste attributen

Nauwkeurigheidsklasse:
0,2s
Toon een precisie:
Vier en een half cijfer (≥100 A: één decimaal; <100 A: twee decimalen; <10 A: drie decimalen)
Invoerbereik:
20A,30A,50A,75A,100A,150A,200A,300A,500A,750A,1000A,1500A,2000A
Overbelastingscapaciteit:
Continue werking bij 1,2 maal de nominale stroom en bij 2 maal de nominale stroom gedurende 1 second
Reactiesnelheid:
Niet langer dan 1 seconde
Impedantie:
≥1MQ
Markeren:

dc ammeter rs485

,

2000a dc current amp meter

,

0.2s accuracy dc ammeter

Basis eigenschappen

Plaats van herkomst:
Shenzhen, provincie Guangdong, China
Merknaam:
Shenzhen Hongyi Tech
Modelnummer:
SH-DCM

Handelsgoederen

Min. bestelaantal:
1
Prijs:
RMB 199
Levertijd:
10-14 dagen
Betalingscondities:
T/T
Levering vermogen:
50

Productbeschrijving

DC Ammeter with 0.2S Accuracy Class and Four and a Half Digits Display Precision Featuring RS485 Communication Interface

 

DC Ammeter Parameters
Measurement Specifications
Parameter Specification
Accuracy Class 0.2S
Display Precision Four and a half digits
(≥100 A: one decimal place
<100 A: two decimal places
<10 A: three decimal places)
Input Range 20A, 30A, 50A, 75A, 100A, 150A, 200A, 300A, 500A, 750A, 1000A, 1500A, 2000A
Overload Capacity Continuous operation at 1.2 times rated current, and at 2 times rated current for 1 second
Response Speed ≤ 1 second
Impedance ≥ 1 MΩ
Power Supply & Output
Parameter Specification
Input Range AC (50-60 Hz); DC 80-300 V or DC 16-75 V
Power Dissipation ≤ 2W
Communication Interface RS485, standard MODBUS-RTU protocol
Alarm Output One normally open contact for overload alarm; one normally open contact for overcurrent alarm
Analog Output 4-20 mA (optional)
Insulation & Reliability
Parameter Specification
Isolation Voltage Power supply - ground, input, output, communication port: 3000 VAC
Communication port - ground: 750 VAC
Insulation Resistance ≥ 100 MΩ
Mean Time Between Failures (MTBF) ≥ 50,000 hours
Environmental Conditions
Parameter Specification
Working Temperature -25℃ to +55℃
Storage Temperature -25℃ to +85℃
Humidity Environment Humidity <95%, no corrosive gases
Altitude < 2500m
Installation Size 93 * 45mm

Neem contact op met onze experts en krijg een gratis consult!

Onze missie is om "High Quality" & "Good Service" & "Fast Delivery" aan te bieden om onze klanten te helpen meer winst te maken.