गुणवत्ता 3KVA 110V UPS Main Module Power Supply Equipment Automatic Startup कारखाना
<
गुणवत्ता 3KVA 110V UPS Main Module Power Supply Equipment Automatic Startup कारखाना
>

3KVA 110V UPS Main Module Power Supply Equipment Automatic Startup

उत्पाद सारांश

UPS Main Module(3KVA/110V) with Pure Sine Wave Output Intelligent Microcomputer Control and Comprehensive Safety Protection Functional Features Utilizes intelligent microcomputer CPU control technology with simple and reliable circuit design Employs SPWM (Pulse Width Modulation) technology to ...

उत्पाद कस्टम विशेषताएँ

इनपुट वोल्टेज रेंज:
220±20%
आवृति सीमा:
50±5%
आउटपुट क्षमता:
1 केवीए, 2 केवीए, 3 केवीए, 5 केवीए, 8 केवीए, 10 केवीए
आउटपुट वोल्टेज:
220±1%
तरंग विरूपण:
टीएचडी ≤ 2%
स्थैतिक बाईपास समय:
≤2ms
प्रमुखता देना:

3KVA 110V UPS Main Module

,

UPS Main Module Power Supply

,

Power Supply Equipment Automatic Startup

मूलभूत गुण

उत्पत्ति के प्लेस:
शेन्ज़ेन, गुआंग्डोंग प्रांत, चीन
ब्रांड नाम:
Shenzhen Hongyi Technology Co.,Ltd
मॉडल संख्या:
एसएच-यूपीएस

व्यापारिक संपत्तियाँ

न्यूनतम आदेश मात्रा:
1
मूल्य:
RMB 5999
प्रसव के समय:
10-14 कार्य दिवस
भुगतान शर्तें:
टी/टी
आपूर्ति की क्षमता:
10

उत्पाद वर्णन

UPS Main Module(3KVA/110V) with Pure Sine Wave Output Intelligent Microcomputer Control and Comprehensive Safety Protection

Functional Features
  • Utilizes intelligent microcomputer CPU control technology with simple and reliable circuit design
  • Employs SPWM (Pulse Width Modulation) technology to deliver pure sine wave with stable frequency and voltage, noise suppression, and low distortion
  • Integrated static bypass switch enables rapid switching between bypass mode and inverter operation
  • Comprehensive Chinese-language LCD/LED status display and alarm signal indication capabilities
  • Fully isolated inverter technology delivering noise-free, pure sinusoidal AC voltage
  • Automatic startup and recovery suitable for unattended environments
  • Intelligent control eliminates need for strict procedural settings during operation
  • Comprehensive safety protection system including input anti-reversal protection, buffering, output short-circuit protection, overload protection, internal overtemperature protection, and input/output high/low voltage detection
  • IGBT components significantly enhance device reliability
  • AC input and output isolated by isolation transformers
  • Excellent overload capacity and strong interference resistance
  • Soft start upon power-up with no surge current
  • Intelligent communication interface RS485 for real-time transmission of device status, voltage/current data, and alarm signals
Working Principle Block Diagrams

Principle Block Diagram of a Dedicated Power UPS

Power-specific UPS - Composition: input isolation transformer, input circuit breaker, rectifier, inverter, output isolation transformer, static bypass switch, DC input circuit breaker, DC isolation diode, control unit, display unit, communication unit

Principle Block Diagram of Dedicated Power UPS

Principle Block Diagram of Power-Specific Inverter

Power-specific inverter - Components: DC input circuit breaker, DC isolation diode, inverter, output isolation transformer, static bypass switch, control unit, display unit, communication unit

Principle Block Diagram of Power-Specific Inverter
Product Models
SH/1KVA /220V SH/2KVA /220V SH/3KVA /220V SH/5KVA /220V SH/8KVA /220V SH/10KVA /220V
SH/1KVA /110V SH/2KVA /110V SH/3KVA /110V SH/5KVA /110V SH/8KVA /110V  
Technical Specifications
Input Characteristics
Parameter Specification
Voltage Range (Vac) 220±20%
Frequency Range (Hz) 50±5%
Number of Phases Single-phase three-wire; Three-phase four-wire
DC Voltage (Vdc) 110V or 220V
Output Characteristics
Output Capacity (KVA) 1 2 3 5 8 10
Voltage (Vac) 220±1%, isolation transformer output
Frequency (Hz) Normal mains power: automatic synchronization and tracking; Power outage: output level 50±0.5%
Waveform Distortion Under linear load, THD ≤ 2%
Phase Difference Under mains power supply, phase difference between output and input ≤2°
Static Bypass Switching Time (ms) ≤2
Inversion Efficiency DC Inverter: ≥87% AC Inverter: ≥83%
Dynamic Response and Recovery Time During 100% load transient, output voltage variation ≥5%, recovers to within ±1% within 25 ms
Overload Capacity 100%-110%: alarm triggered; 110%-150%: alarm for 10 minutes then switch to bypass; >150%: switch to bypass in 1 second
Load Peak Ratio 3:1
Power Factor 0.8 (lag)
Other Features
Feature Specification
Stand-by Time Determined by battery configuration
LCD Display Input/output frequency, input/output voltage, battery voltage, charging voltage, load size, internal temperature
LED Indicators Operation, fault, overload, inversion, and bypass
Alarm Function Abnormal mains power, battery under-voltage, overload, UPS failure
Communication Features Supports dry contact communication and RS485 (with isolation) for remote intelligent monitoring
Protection Functions AC/DC overvoltage protection, overload protection, temperature protection, output overvoltage protection, output short-circuit protection
Insulation Voltage AC 2kV, 1min
Electromagnetic Compatibility EN50091-2
Noise <55 dB (one meter from front of housing)
Working Temperature -10℃ to +40℃
Ambient Humidity 20-95%, no condensation