logo
品質 5KVA 110V UPS Main Module Pure Sine Wave Output Intelligent Microcomputer Control 工場
<
品質 5KVA 110V UPS Main Module Pure Sine Wave Output Intelligent Microcomputer Control 工場
>

5KVA 110V UPS Main Module Pure Sine Wave Output Intelligent Microcomputer Control

製品概要

UPS Main Module(5KVA/110V) with Pure Sine Wave Output Intelligent Microcomputer Control and Comprehensive Safety Protection Functional Features Utilizes intelligent microcomputer CPU control technology with simple and reliable circuit design Employs SPWM (Pulse Width Modulation) technology to ...

製品カスタム属性

入力電圧範囲:
220±20%
周波数範囲:
50±5%
出力容量:
1KVA、2KVA、3KVA、5KVA、8KVA、10KVA
出力電圧:
220±1%
波形ひずみ:
全高調波歪率 ≤ 2%
静的バイパス時間:
≤2ms
ハイライト:

5KVA 110V UPS Main Module

,

5KVA UPS Main Module

,

Pure Sine Wave UPS Main Module

基本プロパティ

起源の場所:
中国広東省深セン
ブランド名:
Shenzhen Hongyi Technology Co.,Ltd
モデル番号:
SH-UPS

取引物件

最小注文数量:
1
価格:
RMB 5999
受渡し時間:
10-14の仕事日
支払条件:
T/T
供給の能力:
10

製品説明

UPS Main Module(5KVA/110V) with Pure Sine Wave Output Intelligent Microcomputer Control and Comprehensive Safety Protection

Functional Features
  • Utilizes intelligent microcomputer CPU control technology with simple and reliable circuit design
  • Employs SPWM (Pulse Width Modulation) technology to deliver pure sine wave with stable frequency and voltage, noise suppression, and low distortion
  • Integrated static bypass switch enables rapid switching between bypass mode and inverter operation
  • Comprehensive Chinese-language LCD/LED status display and alarm signal indication capabilities
  • Fully isolated inverter technology delivering noise-free, pure sinusoidal AC voltage
  • Automatic startup and recovery suitable for unattended environments
  • Intelligent control eliminates need for strict procedural settings during operation
  • Comprehensive safety protection system including input anti-reversal protection, buffering, output short-circuit protection, overload protection, internal overtemperature protection, and input/output high/low voltage detection
  • IGBT components significantly enhance device reliability
  • AC input and output isolated by isolation transformers
  • Excellent overload capacity and strong interference resistance
  • Soft start upon power-up with no surge current
  • Intelligent communication interface RS485 for real-time transmission of device status, voltage/current data, and alarm signals
Working Principle Block Diagrams

Principle Block Diagram of a Dedicated Power UPS

Power-specific UPS - Composition: input isolation transformer, input circuit breaker, rectifier, inverter, output isolation transformer, static bypass switch, DC input circuit breaker, DC isolation diode, control unit, display unit, communication unit

Principle Block Diagram of Dedicated Power UPS

Principle Block Diagram of Power-Specific Inverter

Power-specific inverter - Components: DC input circuit breaker, DC isolation diode, inverter, output isolation transformer, static bypass switch, control unit, display unit, communication unit

Principle Block Diagram of Power-Specific Inverter
Product Models
SH/1KVA /220V SH/2KVA /220V SH/3KVA /220V SH/5KVA /220V SH/8KVA /220V SH/10KVA /220V
SH/1KVA /110V SH/2KVA /110V SH/3KVA /110V SH/5KVA /110V SH/8KVA /110V  
Technical Specifications
Input Characteristics
Parameter Specification
Voltage Range (Vac) 220±20%
Frequency Range (Hz) 50±5%
Number of Phases Single-phase three-wire; Three-phase four-wire
DC Voltage (Vdc) 110V or 220V
Output Characteristics
Output Capacity (KVA) 1 2 3 5 8 10
Voltage (Vac) 220±1%, isolation transformer output
Frequency (Hz) Normal mains power: automatic synchronization and tracking; Power outage: output level 50±0.5%
Waveform Distortion Under linear load, THD ≤ 2%
Phase Difference Under mains power supply, phase difference between output and input ≤2°
Static Bypass Switching Time (ms) ≤2
Inversion Efficiency DC Inverter: ≥87% AC Inverter: ≥83%
Dynamic Response and Recovery Time During 100% load transient, output voltage variation ≥5%, recovers to within ±1% within 25 ms
Overload Capacity 100%-110%: alarm triggered; 110%-150%: alarm for 10 minutes then switch to bypass; >150%: switch to bypass in 1 second
Load Peak Ratio 3:1
Power Factor 0.8 (lag)
Other Features
Feature Specification
Stand-by Time Determined by battery configuration
LCD Display Input/output frequency, input/output voltage, battery voltage, charging voltage, load size, internal temperature
LED Indicators Operation, fault, overload, inversion, and bypass
Alarm Function Abnormal mains power, battery under-voltage, overload, UPS failure
Communication Features Supports dry contact communication and RS485 (with isolation) for remote intelligent monitoring
Protection Functions AC/DC overvoltage protection, overload protection, temperature protection, output overvoltage protection, output short-circuit protection
Insulation Voltage AC 2kV, 1min
Electromagnetic Compatibility EN50091-2
Noise <55 dB (one meter from front of housing)
Working Temperature -10℃ to +40℃
Ambient Humidity 20-95%, no condensation
Note: 1. Due to ongoing product development and improvements, specifications may change without prior notice. 2. The upper limit of the DC range is 15% of the rated voltage (20% for wide ranges), while the lower limit corresponds to 183 V at 220 V rated voltage (92 V at 110 V rated voltage).